TechniSat Digi Meter 9 - All In
TechniSat Digi Meter 9 – All In
TechniSat Digi Meter 9 – All In
Description
Professional Satellite / Terrestrial / QAM / FM Meter / Fibre
This TechniSat meter is 9″ Touch Screen meter with Data Logging , and full Spectrum capability’s
This is the All IN version.- Everything from the 0000/3429 Plus extras.
Includes Wifi Measurement 2.4 and 5G, Includes IPTV and Transport Stream reader.
Technical Data
Article information
EAN
4019588034297
Item no.0000/3429
Weight (Box) 2.79 kg
Weight 1.26 kg
Device (W x H x D) 27.00 x 15.50 x 4.50 cm
Box 51.00 x 27.00 x 8.80 cm
Ambient operating conditions
Ambient temperature -10 … 50 °C
Humidity 10 … 90 %
Display
Type TFT-Farb-Touchdisplay (9″, 16:9)
Frequency range
TV digital & analogue – Radio FM 4 … 930 MHz
Digital & analogue satellite 930 … 2600 MHz
Memory 99 Locations
Programmes 199 Programme Plans
General characteristics
Input impedance 75 Ω
Replaceable input jack F, IEC, BNC
RF input protection max. 60 V AC
RF level 30 … 125 dBµV
Measurement result indication PEGEL/POWER niedrig/hoch
File Manager / PC software
ENCODER/dial Yes
LNB stream measurement0 … 500 mA
Measurements display / classification 0.1 dB (Pegel und Power)
Unit of measurement dBµV/dBm
RBW @ -3dB 100 kHz (FM), 130 kHz (TV), 4 MHz (SAT)
Accuracy of measurement typ. 1,5 dB SAT; 1 dB TV
Measurement stability dB/°C (-10°C – 50°C) 0,03 (TV); 0,1 (SAT)
Automatic power off via timer 5 min Adjustable
Voltage supplyDC 12 V / 3A
Audio 0,5 W Sound/buzzer
Interface USB 2.0
Audio/Video input/output HDMI-Ausgang
Low battery alarm
Measurement DVB-S2
MPEG-2 and MPEG-4 HD
NET. ID
ONID, NID, NIT, TSID, PMT, LCN, VPid, APid, orbit position
FEC (auto. recognition)
1/2, 2/3, 3/4, 4/5, 5/6, 6/7, 7/8, 8/9
Measurement DVB-T
Offset frequency
166 kHz
MER and BER measurement tolerances
1 dB typ. (2 dB Max.)
MER measurement
≤ 38 dB
BER
bBER bis zu 1x10E-5; aBER bis zu 2x10E-8
Automatic recognition and display
Constellation, Guard Interval, FEC
Constellation
COFDM / QPSK, 16-QAM, 64-QAM, 256-QAM
Guard interval
1/4, 19/128, 1/8, 19/256, 1/16, 1/32, 1/128
FEC
1/2, 2/3, 3/4, 5/6, 7/8
Spectrum inverted
automatisch
Automatic quality analysis
FAIL – MARGIN – PASS
Noise Margin / Signal Reserve and SNR accuracy of measurement
1 dB
Measurement SAT
Satellite spectrum analysis
DVB-S, DVB-S2
Reception range
930 … 2600 MHz
DiSEqC “a-b-c-d”
RF voltage
5 – 13 – 18 – 24 V
S.C.R
EN 50494 & EN 50607
LNB LO frequency
0 … 20000 MHz
SPAN
10, 20, 50, 100, 200, 500, FULL SAT, Satexpert
Filter measurement bandwidth
1 MHz und 5 MHz @ -3 dB
db / div
1, 2, 5, 10
Reference level
0 … 130 dBµV
Other configurable spectrum parameters / functions
MAX HOLD (peak memory) / freeze MAX Value, SAT POINTING ideal Parameter-settings for the oreintation of an SAT-antenna
MRK measurement illustration
0.1 dB
Dynamic range display
> 30 dB
Noise Margin / Signal Reserve and SNR accuracy of measurement
1 dB
Symbol rate
2 … 45 MS/s
Measurement TV analog
Multi standard
PAL(M-N-B-G-I-D-K), NTSC M, SECAM L
Frequency range
44 … 870 MHz
RF level measurement range
5 … 125 dBµV
Measurements display
0.1 dB
A/V (audio/video) ratio accuracy
1.5 dB Typ.
Measurement TV Terrestrial
TV spectrum analyser
DVB-S2, DVB-T2, DVB-C, AMTV, UKW, DAB+
Frequency range
4 … 930 MHz
Reception range
4 … 65 MHz
SPAN TV band (spread)
1, 2, 5, 7, 10, 20, 50, 100, 200, 500, FULL, VHF, UHF, 4/66
db / div
5, 10
Dynamic range
60 dB
Measurements display
0.1 dB
Filter measurement bandwidth
TV 130 @ -3 dB
Reference level
0 … 130 dBµV
Automatic power / level position marker
für Digital-Signale im Zentrum des Trägers; für analoge Signale auf dem Video-Träger
Other configurable spectrum parameters / functions
MAX HOLD (max. Wert einfrieren)
INGRESS spectrum
4 … 66 MHz
Leakage / interference radiation measurement
Antenne und Entfernungsparameter einstellbar
Measuring DVB-C
Demodulated QAM signals
DVB-C (Annex A, B, C), Downstream DOCSIS
Symbol rate
2000 … 9000 KS/s
Constellation diagram display
16-, 32-, 64-, 128-, 256-QAM
MER measurement
64-QAM > 36dB; 128-QAM > 38dB; 256-QAM > 40dB
BER measurement
bis zu 1 x 10E-9
Spectrum inverted
automatisch
Multiplex flatness
0.7 dB typ.
Automatic quality analysis
FAIL – MARGIN – PASS
Noise Margin / Signal Reserve and SNR accuracy of measurement
1 dB
C/N measurement tolerance
60 dB im Spectrum typ.
Power supply
Nominal voltage
AC 110 … 240 V
Frequency
50 … 60 Hz
Mains adapter
extern (Steckernetzteil)
Rechargeable battery
Li-Ion 7,4 V / 4,3 Ah
Battery life
bis zu 3 Std. @ 25°C
Battery charging time
2 Std. (um 50 % Kapazität zu erreichen)